homeos/tests
HomeOS Bootstrap 3ed49ee882 fix(automations): honor conditions + atomic cooldown claim (R15)
Codex R15 flagged two P1 correctness bugs in AutomationEngine:
- Conditions were never evaluated — a trigger→condition→action rule ran its
  actions unconditionally. Now every stored condition must match current
  entity state (AND) before actions run; a false condition does NOT touch the
  cooldown clock, so the rule stays armed for its next legitimate trigger.
- Cooldown was read-check-then-save, so concurrent queue workers on a burst of
  state changes could all pass the check and each fire. Now claimed with a
  single conditional UPDATE — exactly one worker wins the race (H5).

+3 tests (condition true/false, cooldown-not-armed-on-failed-condition).
AutomationTest 9 green.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-18 01:15:22 +02:00
..
Feature fix(automations): honor conditions + atomic cooldown claim (R15) 2026-07-18 01:15:22 +02:00
TestCase.php Phase 1: bootstrap — Docker stack, Laravel 13, design system, auth 2026-07-17 21:06:20 +02:00